Fault 1: Press the welding button and the welding head will drop, but it will not rise after welding.

reason:

1. Insufficient air pressure;

2. The solenoid valve is defective;

3. Adjust the air pressure;

4. Maintenance program board;

5. The time adjustment switch is damaged.


Fault 2: The overload light is on during operation.

reason:

1. The welding head is loose;

2. Improper frequency adjustment;

3. The welding head is broken;

4. Excessive pressure;

5. The power of the machine is too small.


Fault 3: The power indicator light is off, the fan of the vibration box is weakened, the vibration cannot be generated, or the welding strength is weakened.

reason:

1. The power supply voltage is low;

2. The input transformer is damaged;

3. Poor contact of the power socket.


Fault 4: Press the welding button, and the welding head will drop immediately when it touches the workpiece and it will rise without vibrating.

reason:

1. The descending stroke has not reached the welding position;

2. Poor contact of the travel switch;

3. Poor pressure trigger system.


Fault 5: The impact of welding head rising or falling is too large.

reason:

1. The buffer adjustment is inappropriate;

2. Buffer adjustment and lock up;

3. The descending speed is set too high;

4. The cylinder has poor cushioning.


Fault 6: The air pressure, power supply, and welding head are all normal but cannot be started.

reason:

1. The emergency up button is in poor contact;

2. The program control circuit is bad;

3. The start button is damaged;

4. The solenoid valve is damaged.


Fault 7: Turn on the main power switch, and the fuse is blown.

reason:

1. Short circuit of ultrasonic power board;

2. The rectifier bridge is short-circuited;

3. The start-up current has a large impact and the fuse capacity is too small.


Fault 8: excessive ultrasonic welding.

reason:

1. The outer dimensions of the work object after melting are different;

2. There is too much damage to the surface of the work;

3. Adjust the lowest point to fine-tune the screw;

4. Replace the welding head with lower amplitude.

5. 溶接時間が長すぎて短縮できない。


欠点 9: 動作するためのエネルギー入力が少なすぎます。

理由:

1. 使用圧力を上げます。

2. 溶接時間を長くします。

3. 振幅を大きくします。

4. より高出力のモデルを使用します。

5. 超音波溶接ヘッドの共振が悪い。